Dr. Choirul Anam, S.Si, M.Si

Biography

Choirul Anam completed his Ph.D in Physics Department, Bandung Institute of Technology (ITB). He received Master degree from University of Indonesia (UI) and the B.Sc degree from Diponegoro University (UNDIP). His research interests are medical image processing and dosimetry for diagnostic radiology, particularly in CT. He has authored and co-authored over 170 papers. He is developer of two software, i.e. IndoseCT and IndoQCT.

An evaluation of computed tomography dose index measurements using a pencil ionisation chamber and small detectors

Q3

JOURNAL OF RADIOLOGICAL PROTECTION (ISSN: 09524746) , vol. 39 , pp. 112-124

Creator: Anam C.

2019

16 cited

An investigation of spatial resolution and noise in reconstructed CT images using iterative reconstruction (IR) and filtered back-projection (FBP)

Q4

JOURNAL OF PHYSICS: CONFERENCE SERIES (ISSN: 17426588) , vol. 1127

Creator: Anam C.

2019

8 cited

A size-specific effective dose for patients undergoing CT examinations

Q4

JOURNAL OF PHYSICS: CONFERENCE SERIES (ISSN: 17426588) , vol. 1204

Creator: Anam C.

2019

1 cited

The impact of head miscentering on the eye lens dose in CT scanning: Phantoms study

Q4

JOURNAL OF PHYSICS: CONFERENCE SERIES (ISSN: 17426588) , vol. 1204

Creator: Anam C.

2019

5 cited

Validation of the tail replacement method in MTF calculations using the homogeneous and non-homogeneous edges of a phantom

Q4

JOURNAL OF PHYSICS: CONFERENCE SERIES (ISSN: 17426588) , vol. 1248

Creator: Anam C.

2019

5 cited

Assessment of patient dose and noise level of clinical CT images: Automated measurements

Q3

JOURNAL OF RADIOLOGICAL PROTECTION (ISSN: 09524746) , vol. 39 , pp. 783-793

Creator: Anam C.

2019

16 cited

An investigation of a CT noise reduction using a modified of wiener filtering-edge detection

Q4

JOURNAL OF PHYSICS: CONFERENCE SERIES (ISSN: 17426588) , vol. 1217

Creator: Anam C.

2019

2 cited

Automated MTF measurement in CT images with a simple wire phantom

Q4

POLISH JOURNAL OF MEDICAL PHYSICS AND ENGINEERING (ISSN: 14254689) , vol. 25 , pp. 179-187

Creator: Anam C.

2019

8 cited

A SIMPLIFIED METHOD for the WATER-EQUIVALENT DIAMETER CALCULATION to ESTIMATE PATIENT DOSE in CT EXAMINATIONS

Q3

RADIATION PROTECTION DOSIMETRY (ISSN: 01448420) , vol. 185 , pp. 42-49

Creator: Anam C.

2019

7 cited

A novel multiple-windows blending of CT images in red-green-blue (RGB) color space: Phantoms study

Q4

SCIENTIFIC VISUALIZATION , vol. 11 , pp. 56-69

Creator: Anam C.

2019

4 cited