Dr. Choirul Anam, S.Si, M.Si

Biography

Choirul Anam completed his Ph.D in Physics Department, Bandung Institute of Technology (ITB). He received Master degree from University of Indonesia (UI) and the B.Sc degree from Diponegoro University (UNDIP). His research interests are medical image processing and dosimetry for diagnostic radiology, particularly in CT. He has authored and co-authored over 170 papers. He is developer of two software, i.e. IndoseCT and IndoQCT.

Automated development of the contrast–detail curve based on statistical low-contrast detectability in ct images

JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS 23 (9), E13719, 2022

Authors: C Anam, A Naufal, T Fujibuchi, K Matsubara, G Dougherty

2022

1 cited

Comparison of central, peripheral and weighted size specific dose in ct to dose results from indosect software

INTERNATIONAL JOURNAL OF RESEARCH AND REVIEW 9 (7), 249-253, 2022

Authors: P Dio, C Anam, E Hidayanto

2022

0 cited

Computational phantoms for investigating impact of noise magnitude on modulation transfer function

INDONESIAN JOURNAL OF ELECTRICAL ENGINEERING AND COMPUTER SCIENCE 27 (3 …, 2022

Authors: C Anam, A Naufal, H Sutanto, G Dougherty

2022

0 cited

Real-time fully automated dosimetric computation for ct images in the clinical workflow: a feasibility study

FRONTIERS IN ONCOLOGY 12, 798460, 2022

Authors: M Porzio, C Anam

2022

0 cited

Investigation of electron contamination on flattened and unflattened varian clinac ix 6x and 15x photon beam based on monte carlo simulation

ATOM INDONESIA 48 (2), 147-158, 2022

Authors: F Haryanto, MF Rhani, C Anam, S Yani

2022

0 cited

Evaluation of radiation dose accuracy calculated using indosect software with direct measurement on polyester-resin phantoms

RADIATION PHYSICS AND CHEMISTRY 201, 110473, 2022

Authors: P Dio, C Anam, E Hidayanto, H Sutanto, RH Asiah, LN Fatichah, ...

2022

0 cited

Automation of slice thickness measurements in computed tomography images of aapm ct performance phantom using a non-rotational method

POLISH JOURNAL OF MEDICAL PHYSICS AND ENGINEERING 28 (3), 133-138, 2022

Authors: AD Ximenes, C Anam, E Hidayanto, A Naufal, DA Rukmana, G Dougherty

2022

0 cited

Implementation of a selective median filter in computed tomography for image quality enhancement

Authors: A Mukmin, C Anam, CE Widodo, A Naufal, FR Arisyi

2022

0 cited

The establishment of institutional diagnostic reference levels (drls) in the cipto mangunkusumo hospital

ATOM INDONESIA 48 (2), 159-167, 2022

Authors: T Amalia, B Zulkarnaien, C Anam, K Nurcahyo, H Tussyadiah, ...

2022

0 cited

An improved method of automated noise measurement system in ct images

JOURNAL OF BIOMEDICAL PHYSICS & ENGINEERING 11 (2), 163, 2021

Authors: C Anam, I Arif, F Haryanto, FP Lestari, R Widita, WS Budi, H Sutanto, ...

2021

8 cited